wk 160ad85051 feat(line): 智电改造线路台账接入 ICC 消防探测器真实同步
- 重建 electric_line 表结构(迁移20261024_icc_line_rebuild.sql并同步db_init/db_seed):删building_id/floor_no/location/icc_device_code占位字段,equip_id改可空,新增imei/gateway_id/type_code/type_name/fire_system_code/fire_system_name/part_unit_loop_code/channel_no/channel_sn/produce_date,gateway_id外键→electric_gateway
- 同步服务IccLineSyncService复用OAuth2真实鉴权分页拉取探测器(POST /detector/subsystem/page,pageSize=50短页停止),按line_code(detectorCode)幂等upsert写icc_sync_log;customer_id由orgCode→customer.icc_code解析、gateway_id由parentCode→electric_gateway.device_code匹配、equip_id同步不填充
- 列表接口返回gateway/type/imei等新字段,keyword检索含imei;前端台账页更新为新列(IMEI/所属网关/探测器类型/回路通道/消防系统/生产日期),保留手动同步按钮与筛选
- 更新系统设计文档electric_line表定义与spec(add-icc-line-sync)
2026-10-24 13:50:32 +08:00

72 lines
6.0 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# 智电线路真实 ICC 同步 Spec(add-icc-line-sync)
## Why
现有 electric_line(智电改造线路台账)为占位实现:表结构是手工设计的占位字段(building/floor/location 等),同步链路 `icc_line_sync.service.ts` 走假的 `ICC_TOKEN` 配置、无真实鉴权。本次依据 ICC 平台接口文档第三节「消防探测器分页查询」(`POST /evo-apigw/evo-fdbu/{version}/detector/subsystem/page`)将线路台账升级为**真实数据同步**:重建表结构(按 DetectorVO 落库字段 + 与 customer/customer_equipment/electric_gateway 三张表的关联),后端替换为真实 OAuth2 拉取(复用 icc_customer_auth),前端台账页补充新字段展示并保留手动同步按钮。
## What Changes
- **表结构变更(BREAKING)**:`electric_line` 按 DetectorVO 重建字段集:
- 删除:`building_id`、`floor_no`、`location`、`icc_device_code`(占位字段无真实数据源)
- `equip_id` 由 `NOT NULL` 改为**可空**(→ customer_equipment,同步不填充,留待手动关联)
- 新增:`imei`、`gateway_id`(→ electric_gateway)、`type_code`、`type_name`、`fire_system_code`、`fire_system_name`、`part_unit_loop_code`、`channel_no`、`channel_sn`、`produce_date`
- 保留:`line_code`(= detectorCode,唯一幂等键)、`line_name`(= detectorName)、`customer_id`(NOT NULL)、`status`(= detectorStatus:01→1 在线 / 02→0 离线)、`synced_at`、`created_at`
- 不落库(仅作关联匹配键):`orgCode`→customer.icc_code 反查 customer_id;`parentCode`→electric_gateway.device_code 反查 gateway_id
- **后端同步真实化**:重写 `icc_line_mapper.ts`(DetectorVO 映射 + 分页解析)与 `icc_line_sync.service.ts`(复用 `getIccAccessToken`/`iccFetch`,POST 分页 pageSize=50 短页停止、全量拉取、按 line_code 幂等 upsert、写 icc_sync_log sync_type=electric_line、失败仅记日志不抛)
- **关联规则**:customer_id 由 orgCode 匹配;gateway_id 由 parentCode 匹配 device_code;equip_id 同步不填充
- **前端台账页更新**:`views/device/line/index.vue` 移除楼层/建筑/位置列,新增探测器类型、IMEI、回路/通道、消防系统、生产日期、网关等列;保留「同步线路」手动按钮与筛选
- **设计文档同步**:更新 `系统设计/表结构新增及变更.md` 补充 electric_line 新结构
- 定时任务 `icc_line_sync`(jobKey 不变,cron */10)、菜单 61、RBAC `/api/electric-lines → device:list`、前端路由 `/device/line` 均沿用既有,无需新增
## Impact
- Affected specs:add-icc-line-ledger(本 spec 升级其占位实现)、add-icc-gateway-sync(复用其真实同步模式与关联表)
- Affected code:
- 后端:`server/src/entity/electric_line.entity.ts`、`server/src/task/icc_line_mapper.ts`、`server/src/service/icc_line_sync.service.ts`、`server/src/service/electric_line.service.ts`(decorate 去掉 building、新增 gateway/类型展示)、`server/src/controller/electric_line.controller.ts`(不动)
- 迁移:`database/migrations/20261011_icc_line_ledger.sql`(重建 electric_line 结构)或新增增量迁移;`database/db_seed.sql` 同步
- 前端:`client/src/views/device/line/index.vue`、`client/src/api/device.ts`(ElectricLine 类型)
- 设计文档:`系统设计/表结构新增及变更.md`
## ADDED Requirements
### Requirement: electric_line 表结构按 DetectorVO 重建
系统 SHALL 将 `electric_line` 重建为与 DetectorVO 对应的字段集,且:
- `line_code` 存 detectorCode(唯一,幂等键)
- `customer_id` NOT NULL,由 orgCode→customer.icc_code 反查
- `gateway_id` 可空,由 parentCode→electric_gateway.device_code 反查
- `equip_id` 可空,同步不填充
#### Scenario: 迁移执行成功
- **WHEN** 执行迁移到生产库
- **THEN** electric_line 包含新字段集,旧字段(building_id/floor_no/location/icc_device_code)被移除,equip_id 可空,索引重建;db_seed.sql 与生产库一致
### Requirement: 真实 ICC 探测器拉取同步
系统 SHALL 复用 `getIccAccessToken`/`iccFetch` 真实鉴权,POST `{baseUrl}/evo-apigw/evo-fdbu/{version}/detector/subsystem/page` 分页全量拉取(pageNum 递增、pageSize=50、短页停止、MAX_PAGES 保护),按 line_code 幂等 upsert,写 icc_sync_log(sync_type=electric_line)。
#### Scenario: 同步成功
- **WHEN** 手动点击「同步线路」或定时任务触发
- **THEN** 返回 {pulled, inserted, updated, skipped, synced};新探测器落库、重复 detectorCode 更新;customer_id 解析失败的行跳过;写成功日志
#### Scenario: 同步失败
- **WHEN** ICC 拉取异常(超时/HTTP 错误/鉴权失败)
- **THEN** 仅写 icc_sync_log 失败日志,不抛业务错误,接口返回 code 200 与当前计数
### Requirement: 前端台账页按新字段展示
系统 SHALL 更新 `views/device/line/index.vue`:删除建筑/楼层/位置列,新增探测器类型、IMEI、回路/通道、消防系统、生产日期、所属网关列;保留筛选(客户/状态/关键词)与「同步线路」手动按钮。
#### Scenario: 页面渲染
- **WHEN** 登录 admin 打开 /device/line
- **THEN** 表格展示新字段列,无 v-html,同步按钮触发 POST /api/electric-lines/sync
## MODIFIED Requirements
### Requirement: 线路台账列表接口(原有)
`GET /api/electric-lines` 保留分页/筛选/RBAC(非 ADMIN 限定 customer_id),decorate 从 building 改为 gateway/类型/IMEI 展示字段,删除 customer_building 关联。
#### Scenario: 列表返回
- **WHEN** 带权限请求 GET /api/electric-lines
- **THEN** 返回行包含 lineCode/lineName/imei/customer/gateway/type/loop/channel/fireSystem/produceDate/status/syncedAt
## REMOVED Requirements
### Requirement: 占位 ICC 同步实现(原 icc_line_sync.service / icc_line_mapper 假配置映射)
**Reason**:无真实鉴权与接口,与 ICC 文档字段不对应。
**Migration**:删除 `ICC_TOKEN` 占位用法,改为复用 icc_customer_auth 真实鉴权;映射按 DetectorVO 重写。